Functions and Features
| Parameter Measurement | Current |
| Voltage | |
| Active/Reactive/Apparent Power | |
| Power Factor | |
| Frequency | |
| Phase and Neutral Line | |
| Wire Line and Phase Line | |
| 3 Phases and Single Phase | |
| 3 Phases and Single Phase | |
| Energy Measurement | Input/Output Active Energy |
| Input/Output Reactive Energy | |
| Apparent Energy | |
| 1 Channel Pulse Output | |
| 1 Channel Pulse Output | |
| Demand Statistics | Current |
| Active/Reactive/Apparent Power | |
| Current Value and Max. | |
| Current Value and Max. | |
| Max and Min | Record the max, min and time of all measurement parameters |
| Restoration Rate | 8 Restoration Stages; 4 Restoration Rate can be set |
| Power Quality | Harmonic Distortion |
| 31 times Harmonic Analysis | |
| Current and Voltage | |
| Current and Voltage | |
| Communication Protocol | MODBUS-RTU |
| Display | STN LCD Display with big screen |
| Real-Time Clock | |
| Year/Month/ Day/Hour/Minute/Second | |
| Relay Output Module | 2 Channels Relay Output |
| Programmable Alarm Setting of exceeding the limit | |
| Remote Control | |
| Analog Input and Output Module | 1 Channel Analog Input Measurement for 4-20mA DC |
| 1 Channel Analog Input Measurement for 0-5V DC | |
| 2 Channels Analog Output for 4-20mA DC |
| Electrical characteristics | ||
| Measure Type | 3P3W AC system, 3P4W AC system | |
| Sampling rate | 128 points per cycle | |
| Data refresh rate | 1S | |
| Measure accuracy | Current | ±0.2%FS |
| Voltage | ±0.2%FS | |
| Power | 0.5S | |
| Frequency | ±0.001Hz | |
| Active Energy | 0.5S | |
| Reactive Energy | 1.0S | |
| DC input(AI) | 0.5% FS | |
| DC output(AO) | 0.5% FS | |
| Input voltage characteristics | Measure Voltage | 3 *220/380V(Directly input) |
| 3 * 57.7/100V(PT secondary side) | ||
| Allowed overload capability | 1.2 times / continuous | |
| input resistance | 300KΩ | |
| Input current characteristics | Measure current | 5A (CT Secondary side)Or 1A (CT Secondary side) |
| Allowed overload capability | 1.2 times / continuous | |
| input resistance | <0.1Ω | |
| Binary input | Working voltage | 12~24 VDC |
| input resistance | 12KΩ | |
| Isolation voltage | 2KV | |
| Relay Output | Node type | Mechanical contact |
| Node capability | 220 VAC/5A, 30 VDC/5A | |
| 4-20mA DC input measurement | Measure current | 4-20mA |
| Allowed overload capability | 1.2 times / continuous | |
| input resistance | 10Ω | |
| Isolation voltage | 2KV | |
| 0-5V DC input measurement | Measure Voltage | 0-5V |
| Allowed overload capability | 1.2 times / continuous | |
| input resistance | 12.5KΩ | |
| Isolation voltage | 2KV | |
| 4-20mA DC output | Open-circuit Voltage | 15VDC |
| Load capability | ≤600Ω | |
| Isolation voltage | 2KV | |
| Power supply | AC | 100~240 VAC/45-65Hz |
| DC | 100~375 VDC | |
| Power consumption | < 3W | |
| Mechanical performance | ||
| Weight | 0.5kg | |
| IP Protection Level | Meter Panel IP52, Meter Host IP30 | |
| Dimension | Host | 96 X 96 X 72 mm |
| Host+modules | 96 X 96 X 120 mm | |
| Working temperature | Display screen | -20~70℃ |
| Meter | -25~70℃ | |
| storage temperature | Meter+display screen | -40~85℃ |
| Relative humidity | 5% - 90%RH, No condensation | |
| EMC | ||
| Antistatic discharge interference | IEC 61000-4-2, Level 4 | |
| Anti-fast transient group pulse | IEC 61000-4-4, Level 4 | |
| Anti-surge | IEC 61000-4-5, Level 3 | |
| Resistance to power frequency magnetic field | IEC 61000-4-8, Level 3 | |
| Electrical insulation performance | ||
| Insulation resistance | GB/T13729, >50MΩ | |
| Power frequency withstand voltage | GB/T13729, AC 2KV 50Hz /1min | |
| Impulse voltage | GB/T13729, 5KV, 1.2/50us | |
| Model Specification: PMC200S-①-②-③-④-⑤ | |
| ①Model code: | |
| 1 | 57.7/100V Rated measurement voltage, 5A Rated measurement current |
| 2 | 57.7/100V Rated measurement voltage, 1A Rated measurement current |
| 3 | 220/380V Rated measurement voltage, 5A Rated measurement current |
| 4 | 220/380V Rated measurement voltage, 1A Rated measurement current |
| ②Model code: | |
| 1 | Power supply: 85~264 VAC/45-65Hz, 100~300 VDC |
| ③Model code: | |
| 0 | Without DI |
| 4 | 4 Channels DI |
| ④Model code: | |
| 0 | Without relay output |
| 1 | Optional 1 channel relay output(RL1+, RL1- port) |
| 2 | Optional 2 channels relay output |
| ⑤Model code: | |
| ab | ab is a 2 integer, a means AI01 port optional for AI/AO modules, b means AI02 port optional for AI/AO |
| 0 –none | |
| 1 - 0-5V DC analog input measure(AI) | |
| 2 - 4-20mA DC analog input measure(AI) | |
| 3 - 4-20mA DC analog output(AO) | |
| For example: ab = 00, Means AI 01 port is not equipped with AI/AO module, AI02 port is not equipped with AI/AO module | |
| ab = 12, Means AI01 port is equipped with 0-5V DC analog input measure AI/AO module, AI02 port is equipped with 4-20mA DC analog input measure AI/AO module | |
For example: Order model: PMC200S-3-1-4-2-12.
Means PMC200S rated measure 220V/380V, 5A, working power supply as 85-264VAC/45-65HZ, Optional with 4channels binary input(DI), 2 channels relay output; 1 channel 0-5V DC analog input measure(AI01 port), 1 channel 4-20mA DC analog input measure(AI02 port).